{"title":"Transmitters Din Rail","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1\u003e\u003cb\u003eVibration, Speed \u0026amp; Temperature Din Rail Transmitters\u003c\/b\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\t(Vibration Transmitters, Temperature Transmitters, Speed Transmitters and TSI Transmitters)\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e Reliability Direct Inc. is proud to offer STI Vibration Monitoring's innovative CMCP500 series Din Rail Mounted single channel Vibration Transmitter\/Monitors. Transmitters include an OK Circuit and a Buffered BNC Connector. With the optional Alarm Module they are a fully functional single channel monitors with OK, Alert and Danger Alarms. They are CSA\/UL Class 1 Division 2 and CE approved. The CMCP500 series Vibration Transmitters may be used on a wide spectrum of machinery from Motor driven Fans and Pumps to large Turbine Generators. Contact us for assistance on any of your vibration monitoring and protection needs.\u003cbr\u003e\u003cbr\u003e\n\u003cdiv align=\"center\"\u003e\n\u003ca href=\"http:\/\/www.reliabilitydirectstore.com\/kb_results.asp?cat=15\" target=\"_self\" title=\"Knowledge Base Articles on Vibration\"\u003ePlease Visit our Knowledge Base for more Information on Vibration!\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e","products":[{"product_id":"cmcp525-acceleration-transmitter","title":"CMCP525 Acceleration Transmitter","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cimg align=\"right\" alt=\"\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20transmitter_20approval_20label_20v1.jpg?v=1784665444\" style=\"width: 201px; height: 171px;\"\u003eThe CMCP525 Acceleration In\/Acceleration Out Transmitter is available in either \"Peak\" or \"True RMS\" signal detection versions. The CMCP525 is compatible with all voltage output accelerometers, and provides a 4-20 mA output proportional to the overall measurement. Each unit provides constant current power for the accelerometer, checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA DC current that is proportional to a user selected range of 5, 10, 15, 20 or 25 g's with a 100 mv\/g Input. CSA and UL Class 1, Div 2, B-D Approved.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe Optional Alarm Module provides OK, Alert and Danger Relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\n\u003c\/p\u003e\u003cdiv\u003e\u003cspan style=\"color: rgb(255, 0, 0); font-weight: bold\"\u003eCustom Input and Output Calibrations are Available on Request.\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003c\/p\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms relays and trip multiply are\navailable with the Monitor version.\u003c\/span\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Monitor Approval Label\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20monitor_20approval_20label_20v1.jpg?v=1784665447\" style=\"margin-left: 8px; width: 195px; height: 162px;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms - \u003c\/span\u003eThe CMCP500A Series Monitors have\ntwo independent set points, with LED alarm indicators and output relay contacts\n(Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110%\nof full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay\ncontacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eRelay contacts can be independently\nconfigured by the user for either Normally Open (NO) (Standard) or Normally\nClosed (NC) operation. Relays are normally de-energized and can be configured\nfor latching or non-latching (standard) operation. Latched alarms may be reset\nlocally or by remote contact closure. \u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors\nhave set point multiplication of 3X via contact closure (2X available). To\navoid tripping the alarms during machine start-up.\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003chr style=\"WIDTH: 100%; HEIGHT: 2px\"\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eDocuments Available:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"True RMS, -01R \/ Transmitter Only","offer_id":48343223337172,"sku":"CMCP525","price":495.0,"currency_code":"USD","in_stock":true},{"title":"True RMS, -01R \/ with Alarm Module (A)","offer_id":48343223369940,"sku":"CMCP525","price":495.0,"currency_code":"USD","in_stock":true},{"title":"Peak, -01P \/ Transmitter Only","offer_id":48343223402708,"sku":"CMCP525","price":495.0,"currency_code":"USD","in_stock":true},{"title":"Peak, -01P \/ with Alarm Module (A)","offer_id":48343223435476,"sku":"CMCP525","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP525-2.jpg?v=1785177908"},{"product_id":"cmcp530-velocity-transmitter","title":"CMCP530 Velocity Transmitter","description":"\u003cp\u003e\u003cimg align=\"right\" alt=\"\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20transmitter_20approval_20label_20v1.jpg?v=1784665444\" style=\"width: 201px; height: 171px;\"\u003eThe CMCP530 Accelerometer based \nVelocity Transmitter is available in either \"Peak\" or \"True RMS\" signal \ndetection versions and English or Metric scaling. The CMCP530 is \ncompatible with all 100mV\/g output accelerometers, and provides a 4-20 \nmA output proportional to the overall measurement. Each unit provides \nconstant current power for the accelerometer, checks for faults, \nprocesses the vibration signal to determine overall amplitude, and \noutputs a 4-20 mA dc current that is proportional to a user selectable \nrange of 0.5, 1.0, 1.5, 2.0 and 2.5 in\/sec (metric equivalent of 12.7, \n25.4, 38.1, 50.8 and 63.5 mm\/sec) with a 100 mv\/g Input. Combining \ntransmitters with an existing PLC or DCS system results in a high \ndensity, low cost vibration monitoring system.\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv\u003eThe Optional Alarm Module provides ok, \nalert and danger relays, selectable time delay, trip multiply, bypass \nand 0 to 5 VDC outputs for displays. The relay outputs can be used to \ntrigger machine shut-down or other alarms.\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-weight: bold\"\u003eCustom Input and Output Calibrations are Available on Request.\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms relays and trip multiply are\navailable with the Monitor version\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Monitor Approval Label\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20monitor_20approval_20label_20v1.jpg?v=1784665447\" style=\"margin-left: 8px; width: 195px; height: 162px;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms - \u003c\/span\u003eThe CMCP500A Series Monitors have\ntwo independent set points, with LED alarm indicators and output relay contacts\n(Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110%\nof full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay\ncontacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.\u003c\/p\u003e\n\u003cp style=\"margin:0in;margin-bottom:.0001pt\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0in 0in 0.0001pt; text-align: justify;\"\u003eRelay contacts can be independently\nconfigured by the user for either Normally Open (NO) (Standard) or Normally\nClosed (NC) operation. Relays are normally de-energized and can be configured\nfor latching or non-latching (standard) operation. Latched alarms may be reset\nlocally or by remote contact closure. \u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\"margin: 0in 0in 0.0001pt; text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors\nhave set point multiplication of 3X via contact closure (2X available). To\navoid tripping the alarms during machine start-up.\u003cbr\u003e\n\u003c\/div\u003e\u003cp style=\"margin:0in;margin-bottom:.0001pt\"\u003e\n\u003c\/p\u003e\u003chr style=\"WIDTH: 100%; HEIGHT: 2px\"\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eDocuments Available:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"True RMS, -01R \/ Transmitter Only","offer_id":48343223501012,"sku":"CMCP530","price":495.0,"currency_code":"USD","in_stock":true},{"title":"True RMS, -01R \/ with Alarm Module (A)","offer_id":48343223533780,"sku":"CMCP530","price":495.0,"currency_code":"USD","in_stock":true},{"title":"Peak, -01P \/ Transmitter Only","offer_id":48343223566548,"sku":"CMCP530","price":495.0,"currency_code":"USD","in_stock":true},{"title":"Peak, -01P \/ with Alarm Module (A)","offer_id":48343223599316,"sku":"CMCP530","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP530-2.jpg?v=1785177931"},{"product_id":"cmcp530-iso-velocity-transmitter","title":"CMCP530 ISO Velocity Transmitter","description":"\u003cp\u003e\u003cimg align=\"right\" alt=\"\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20transmitter_20approval_20label_20v1.jpg?v=1784665444\" style=\"width: 201px; height: 171px;\"\u003e The CMCP530 is \ncompatible with all 100mV\/g output accelerometers, and provides a 4-20 \nmA output proportional to the overall measurement. Each unit provides \nconstant current power for the accelerometer, checks for faults, \nprocesses the vibration signal to determine overall amplitude, and \noutputs a 4-20 mA dc current that is proportional to a user selectable \nrange of 0.5, 1.0, 1.5, 2.0 and 2.5 in\/sec (metric equivalent of 12.7, \n25.4, 38.1, 50.8 and 63.5 mm\/sec) with a 100 mv\/g Input. Combining \ntransmitters with an existing PLC or DCS system results in a high \ndensity, low cost vibration monitoring system.\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv\u003eThe Optional Alarm Module provides ok, \nalert and danger relays, selectable time delay, trip multiply, bypass \nand 0 to 5 VDC outputs for displays. The relay outputs can be used to \ntrigger machine shut-down or other alarms.\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-weight: bold\"\u003eCustom Input and Output Calibrations are Available on Request.\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms relays and trip multiply are\navailable with the Monitor version\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Monitor Approval Label\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500_20monitor_20approval_20label_20v1.jpg?v=1784665447\" style=\"margin-left: 8px; width: 195px; height: 162px;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms - \u003c\/span\u003eThe CMCP500A Series Monitors have\ntwo independent set points, with LED alarm indicators and output relay contacts\n(Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110%\nof full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay\ncontacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.\u003c\/p\u003e\n\u003cp style=\"margin:0in;margin-bottom:.0001pt\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0in 0in 0.0001pt; text-align: justify;\"\u003eRelay contacts can be independently\nconfigured by the user for either Normally Open (NO) (Standard) or Normally\nClosed (NC) operation. Relays are normally de-energized and can be configured\nfor latching or non-latching (standard) operation. Latched alarms may be reset\nlocally or by remote contact closure. \u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\"margin: 0in 0in 0.0001pt; text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors\nhave set point multiplication of 3X via contact closure (2X available). To\navoid tripping the alarms during machine start-up.\u003cbr\u003e\n\u003c\/div\u003e\u003cp style=\"margin:0in;margin-bottom:.0001pt\"\u003e\n\u003c\/p\u003e\u003chr style=\"WIDTH: 100%; HEIGHT: 2px\"\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eDocuments Available:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Transmitter Only","offer_id":48343223992532,"sku":"CMCP530-ISO","price":455.0,"currency_code":"USD","in_stock":true},{"title":"with Alarm Module (A)","offer_id":48343224025300,"sku":"CMCP530-ISO","price":455.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP530-2.jpg?v=1785177931"},{"product_id":"cmcp540-radial-vibration-transmitter","title":"CMCP540 Radial Vibration Transmitter","description":"\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Transmitter Approval Label\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1_7817883b-dba4-48af-a492-330d88e44f43.jpg?v=1784665492\" style=\"margin-left: 8px;\"\u003eThe CMCP540 Displacement Transmitter is compatible with all manufactures Eddy Probe or Proximity Probe Systems with a voltage output of 200 mv\/mil and is available in English or Metric scaling. The CMCP540 checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user selected range of 0 to 5, 10, 15, 20 or 25 mils (0 to 127, 254, 381, 508 or 635 microns). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003eThe Optional Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-weight: bold; color: rgb(255, 0, 0);\"\u003eAlarms relays and trip multiply are available with the Monitor version.\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style=\"font-weight: bold;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Transmitter Approval Label\" border=\"0px\" src=\"https:\/\/www.reliabilitydirectstore.comhttps:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1_7817883b-dba4-48af-a492-330d88e44f43.jpg?v=1784665492\" style=\"margin-left: 8px;\"\u003e\u003c\/span\u003eAlarms\u003c\/span\u003e - The CMCP500A Series \nMonitors have two independent set points, with LED alarm indicators and \noutput relay contacts (Alert and Danger). Set points are adjustable via \npotentiometer, from 0 to 110% of full scale. Each has an adjustable \ndelay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc \nor 250 Vac for resistive loads. \u003cbr\u003e\n\u003cbr\u003e\nRelay contacts can be independently configured by the user for either \nNormally Open (NO) (Standard) or Normally Closed (NC) operation. Relays \nare normally de-energized and can be configured for latching or \nnon-latching (standard) operation. Latched alarms may be reset locally \nor by remote contact closure. \u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors \nhave set point multiplication of 3X via contact closure (2X available). \nTo avoid tripping the alarms during machine start-up. \u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); font-weight: bold; font-size: 10pt;\"\u003eCustom Input and Output Calibrations are Available on Request.\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003chr style=\"width: 100%; height: 2px; margin-left: 0px; margin-right: 0px;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" font-weight: bold; text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003eDocuments Available:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003chr style=\"width: 100%; height: 2px; margin-left: 0px; margin-right: 0px;\"\u003e\n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Transmitter Only","offer_id":48343228907732,"sku":"CMCP540","price":495.0,"currency_code":"USD","in_stock":true},{"title":"with Alarm Module (A)","offer_id":48343228940500,"sku":"CMCP540","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP525-2_c12e3b09-e930-4354-9f73-1f028233f300.jpg?v=1792116814"},{"product_id":"cmcp535-velocity-to-displacement-transmitter","title":"CMCP535 Velocity to Displacement Transmitter","description":"\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1.jpg?v=1784665490\"\u003eThe CMCP535 Displacement Transmitter is compatible with both 100mV\/In\/Sec Piezo Electronic (Accelerometer w\/Velocity Output) and 500mV\/In\/Sec Electro Mechanical Velocity Transducers and is available in English or Metric scaling. The CMCP535 provides constant current power (if required), checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user selected range of 5, 10, 15, 20 or 25 mils (metric equivalent of 127, 254, 381 508 or 635 microns). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003eThe Optional Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold; color: rgb(255, 0, 0);\"\u003eAlarms relays and trip multiply are available with the Monitor version.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"\" border=\"0px\" src=\"https:\/\/www.reliabilitydirectstore.comhttps:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1.jpg?v=1784665490\"\u003e\u003c\/span\u003eAlarms\u003c\/span\u003e - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads. \u003cbr\u003e\u003cbr\u003eRelay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure. \u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up. \u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); font-weight: bold; font-size: 10pt;\"\u003eCustom Input and Output Calibrations are Available on Request.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\"\"\u003e\n\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv style=\"FONT-FAMILY: Verdana\"\u003e\n\u003chr style=\"WIDTH: 100%; HEIGHT: 2px\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"FONT-FAMILY: Verdana\"\u003e\n\u003cspan style=\"FONT-FAMILY: Times New Roman; FONT-SIZE: 10pt\"\u003e\u003cspan style=\"FONT-FAMILY: Verdana; FONT-SIZE: 10pt; FONT-WEIGHT: bold\"\u003e\u003cspan style=\"FONT-FAMILY: Times New Roman; FONT-SIZE: 10pt\"\u003e\u003cspan style=\" font-size: 10pt;\"\u003eDocuments Available:\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Transmitter Only","offer_id":48343229038804,"sku":"CMCP535","price":495.0,"currency_code":"USD","in_stock":true},{"title":"with Alarm Module (A)","offer_id":48343229071572,"sku":"CMCP535","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP525-2_a04ce370-83be-4ea6-a38e-83ebfd69214d.jpg?v=1792116832"},{"product_id":"cmcp545-thrust-position-transmitter","title":"CMCP545 Thrust Position Transmitter","description":"\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Transmitter Approval Label\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1.jpg?v=1784665490\" style=\"margin-left: 8px;\"\u003eThe CMCP545 Position (Thrust) Monitor is compatible with all manufactures Eddy Probe or Proximity Probe Systems with a voltage output of 100 or 200 mv\/mil and is available in English and Metric scaling. The CMCP545 checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to range of 0 to 80 mils (40-0-40) or the Metric equivalent of 0 to 2 mm (1.0-0-1.0 mm). Internal Jumpers select normal motion towards or away from sensor. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. \u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt;\"\u003eThe Optional Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-weight: bold; color: rgb(255, 0, 0);\"\u003eAlarms relays and trip multiply are available with the Monitor version.\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style=\"font-weight: bold;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Transmitter Approval Label\" border=\"0px\" src=\"https:\/\/www.reliabilitydirectstore.comhttps:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1.jpg?v=1784665490\" style=\"margin-left: 8px;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms\u003c\/span\u003e - The CMCP500A Series \nMonitors have two independent set points, with LED alarm indicators and \noutput relay contacts (Alert and Danger). Set points are adjustable via \npotentiometer, from 0 to 110% of full scale. Each has an adjustable \ndelay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc \nor 250 Vac for resistive loads. \u003cbr\u003e\n\u003cbr\u003e\nRelay contacts can be independently configured by the user for either \nNormally Open (NO) (Standard) or Normally Closed (NC) operation. Relays \nare normally de-energized and can be configured for latching or \nnon-latching (standard) operation. Latched alarms may be reset locally \nor by remote contact closure. \u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors \nhave set point multiplication of 3X via contact closure (2X available). \nTo avoid tripping the alarms during machine start-up. \u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); font-weight: bold; font-size: 10pt;\"\u003eCustom Input and Output Calibrations are Available on Request.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eBuffered Output:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eA BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFault Detection:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eOn board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to \u0026lt;2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cp style=\" text-align: justify;\"\u003e\u003cspan style=\"font-weight: bold; font-size: 10pt;\"\u003eFilters:\u003c\/span\u003e\u003c\/p\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eFor applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB\/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\"\"\u003e\n\u003chr style=\"width: 100%; height: 2px; margin-left: 0px; margin-right: 0px;\"\u003e\n\u003c\/div\u003e\n\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDocuments Available:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cbr style=\"\"\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Transmitter Only","offer_id":48343229300948,"sku":"CMCP545","price":495.0,"currency_code":"USD","in_stock":true},{"title":"with Alarm Module (A)","offer_id":48343229333716,"sku":"CMCP545","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP545-2.jpg?v=1792116833"},{"product_id":"cmcp575-speed-transmitter","title":"CMCP575 Speed Transmitter","description":"\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eThe CMCP575 Isolated Speed Three-Wire Transmitter is one in a family of \nthe 500 Series Transmitters that provide field mounted efficiency and \nease of wiring in a compact DIN package. The CMCP575 accepts a frequency\n or pulse rate input and converts it to a standard process signal \noutput, 4-20mA for interfacing directly with PLC's, DCS's and process \ncomputers.\n\nThe CMCP575 provides independent linearity equivalent to 14-bit digital \naccuracy and include user friendly features such as wide ranging and \nnon-interactive zero and span controls. The power range is 15 to 42 VDC @\n 28mA typical.\u003cbr\u003e\u003cbr\u003eThe CMCP-575 Speed Transmitters are compatible with proximity probe or Hall effect inputs, they provide a 4-20mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20mA dc current that is proportional to a user specified range such as 0-5,000 RPM. Combining transmitters with an existing PLC or DCS system results in a high density, low cost monitoring system.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDefault unit priced above is configured for one input per revolution and 5,000 rpm full scale range.\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cspan style=\"font-weight: bold; color: rgb(84, 141, 212);\"\u003e\u003cbr\u003eCustom Input and Output Configurations Available On Request - Call for Pricing\u003c\/span\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 16px;\"\u003eFeatures:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eEasy Setup!\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.031 to 38,000 Hz.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.1% Accuracy\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cspan style=\"\"\u003eRepeatability: ±0.002% typical\u003c\/span\u003e\u003cspan style=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e4-20mA Output\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e15 to 42 VDC, 28mA typical\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eReverse Polarity Protection\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eCE Approved\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eDin Rail Mount\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cspan style=\" font-weight: bold;\"\u003e\u003cbr\u003eDisplays And Assemblies:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"\"\u003eVarious display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"\"\u003eMounting: 32mm (G Style) or 35mm (T Style) DIN Rail.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e \u003cspan style=\"\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);  background-color: initial; letter-spacing: 0px;\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003c\/p\u003e\u003ctable border=\"1\" style=\"box-sizing: border-box; border-spacing: inherit;\" width=\"600\"\u003e\u003ctbody style=\"box-sizing: border-box;\"\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd bgcolor=\"#000000\" colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"590\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; color: rgb(255, 255, 255);  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eInput Signals\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eVoltage (Amplitude):\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e10 mV-100 Vrms (0-5kHz); 50 mV to 50 Vrms (1 kHz to 38 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eContact:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eDry, 2 mA @ 24 VAC rating\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eFrequency Range:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e0-0.031 Hz to 0-38 kHz full scale\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd bgcolor=\"#000000\" colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"584\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; color: rgb(255, 255, 255);  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput Signals\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eType:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e4-20 mA DC; 0-20 mA DC; 0-10 mA DC; 0-1 mA DC; 1-5 VDC; 0-5 VDC; 0-10 VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput Loop Drive Capability:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cimg src=\"http:\/\/stiweb.com\/images\/cmcp571.gif\" style=\"box-sizing: border-box; max-width: 100%; border: none !important;\"\u003e\u003cbr style=\"box-sizing: border-box;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd rowspan=\"3\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eV Supply:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"3\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"76\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e15 to 42 VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eI out\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"4\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"322\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e4-20 mA or 0-20 mA\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eV supply\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e15\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e24\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"80\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e36\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"80\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e42\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eR(ohms)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e500\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"81\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e950\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"80\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e1550\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"80\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e1850\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd bgcolor=\"#000000\" colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"584\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; color: rgb(255, 255, 255);  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003ePerformance\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eCalibrated Accuracy:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.1%\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eIndependent Linearity:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.025% max\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eRepeatability:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.005% max., ±0.002% typ.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eZero TC:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.005% of span max\/°C\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eSpan TC:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.005% of span max\/°C\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eLoad Effect:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.005% zero to full load\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput Ripple:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e10 mV P\/P maximum\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eResponse Time:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e350 milliseconds (10 to 90% step response)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eBandwidth:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e(-3 db): 120 Hz output response\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eTemperature Range:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\n\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e-25° to 185°F (-31° to 85°C) operating; -40° to 200°F (-40° to 93°C) storage\u003c\/span\u003e\u003c\/p\u003e\u003c\/span\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003ePower Supply Effect:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e±0.005% of span, max.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eIsolation:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eInput\/output\/case: 1000 VDC or 600 VAC\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"584\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eNote: All accuracies are given as a % of span.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd bgcolor=\"#000000\" colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"584\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; color: rgb(255, 255, 255);  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003ePower\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e15 to 42 VDC:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\n\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e28 mA typical; 33 mA maximum\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eReverse polarity and transient protection included\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\u003ctd bgcolor=\"#000000\" colspan=\"7\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"584\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; color: rgb(255, 255, 255);  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eMechanical\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eElectrical Classification:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eGeneral purpose\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eConnection:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eScrew, compression type, accepts up to 14 AWG\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eControls:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eInput SPAN and ZERO push buttons, Input Hsyteresis potentiometer, Output Span and Zero potentiometers\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eMounting:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003eDIN rail\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eWeight:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cspan style=\"font-size: 16px;\"\u003e4 oz. (115 grams)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"box-sizing: border-box;\"\u003e\n\u003ctd style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"105\"\u003e\u003cp style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box;  font-weight: bold;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eHousing:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\" style=\"box-sizing: border-box; line-height: 1.42857; color: rgb(0, 0, 0) !important; \" width=\"479\"\u003e\u003cspan style=\"box-sizing: border-box; \"\u003e\u003cp align=\"left\" style=\"box-sizing: border-box; margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eRugged Krilen for protection against corrosion, moisture and dust\u003c\/span\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":48343230513364,"sku":"CMCP575","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP575-2.jpg?v=1785177955"},{"product_id":"cmcp590-acceleration-enveloping-ge-transmitter","title":"CMCP590 Acceleration Enveloping gE Transmitter","description":"\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-size: 10pt; \"\u003e\u003cimg align=\"right\" alt=\"CMCP500 Transmitter Approval Label\" border=\"0px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/cmcp500-transmitter-approval-label-v1.jpg?v=1784665490\" style=\"margin-left: 8px;\"\u003eThe CMCP590 Transmitter are a 4-20mA enveloped acceleration transmitter. Used in with a 100mV\/g accelerometer, it processes the dynamic vibration acceleration input signal to defects in over-rolling bearing defects or gearbox problems.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003cspan style=\"font-weight: bold; color: rgb(255, 0, 0);\"\u003eAlarms relays and trip multiply are available with the Monitor version.\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAlarms\u003c\/span\u003e - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads. \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003eRelay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure. \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003cspan style=\"font-weight: bold;\"\u003eTrip Multiply\u003c\/span\u003e - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up. \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv style=\" text-align: justify;\"\u003e\n\u003chr style=\"width: 100%; height: 2px; margin-left: 0px; margin-right: 0px;\"\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cspan style=\"font-weight: bold; font-size: 10pt; \"\u003eDocuments Available:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e      \n\u003c\/div\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Transmitter Only","offer_id":48343239655636,"sku":"CMCP590","price":550.0,"currency_code":"USD","in_stock":true},{"title":"with Alarm Module (A)","offer_id":48343239688404,"sku":"CMCP590","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP525-2_44556a8e-a08e-4d3f-b979-74668aad52aa.jpg?v=1792116833"},{"product_id":"cmcp797-2-two-channel-active-buffer","title":"CMCP797-2 Two Channel Active Buffer","description":"\u003cspan id=\"product_description\"\u003eThe \u003cb\u003eCMCP797-2 Two Channel Active Buffer\u003c\/b\u003e \u003cbr\u003e\u003c\/span\u003e\u003cspan id=\"product_description\"\u003e\u003cspan id=\"product_description\"\u003e\u003cul style=\"box-sizing: border-box; margin-bottom: 11px; color: rgb(0, 0, 0);  letter-spacing: normal; background-color: rgb(255, 255, 255);\"\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eTwo Inputs \/ 6 Outputs\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e3 Active Buffer Outputs Per Input\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eAccelerometer or Proximity Probe Signal\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e+\/-24VDC Powered\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e0 to 150kHz Frequency Range\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eOptional Constant Current Power for IEPE Accelerometers\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eDC Coupled (Bias\/Gap on Outputs)\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003ePower “On” LED\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eDin Rail Mounted\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eOptional TBus® Power Wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; margin-bottom: 11px; color: rgb(0, 0, 0);  letter-spacing: normal; background-color: rgb(255, 255, 255);\"\u003eThe CMCP797-2 Two Channel Active Buffer Module accepts two inputs from any vibration sensor and provides three (3) Active Buffered Outputs, including one BNC output. The CMCP797-2 has two selector switches to configure the unit for either +V or -V input signals and also for sensor power. The CMCP797-2 is perfect for applications where a signal needs to be split reliably or where a BNC output is needed for portable data collection.\u003c\/p\u003e\n\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cdiv id=\"ProductDetail_TechSpecs_div\" style=\"\"\u003e\n\u003c\/div\u003e\u003cspan id=\"product_description\"\u003e\u003cspan id=\"product_description\"\u003e\u003c\/span\u003e\u003c\/span\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":48343244865748,"sku":"CMCP797-2","price":595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/CMCP797-2-2.jpg?v=1785178464"},{"product_id":"cmcp700s-cv-case-vibration-transmitter","title":"CMCP700S-CV Case Vibration Transmitter","description":"\u003cdiv style=\"border:2px solid #c0392b;background:#fdecea;padding:12px 16px;margin-bottom:16px;border-radius:4px;\"\u003e\n\u003cp style=\"margin:0;font-weight:bold;color:#c0392b;\"\u003eDISCONTINUED: The CMCP700S-CV has been discontinued by STI and is no longer available.\u003c\/p\u003e\n\u003cp style=\"margin:6px 0 0 0;\"\u003eIt has been replaced by the \u003ca href=\"\/products\/cmcp700s-cvt-vibration-temperature-transmitter\"\u003e\u003cb\u003eCMCP700S-CVT Dual Parameter Vibration and Temperature Transmitter\u003c\/b\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003eThe \u003cb\u003eCMCP700S-CV (Case Vibration) \u003c\/b\u003eaccepts an Accelerometer or Velocity\nSensor Input. 4ma Constant Current Power for the sensor is provided.\nStandard input is 100 mv\/g or 100 mv\/in\/sec (4 mv\/mm\/sec). The\nCMCP700S-CV provides an output in either Acceleration (g’s) or Velocity\n(in\/sec, mm\/sec).  \u003cbr\u003e\u003cbr\u003eWith a Velocity Sensor Input either a Velocity or\nDisplacement (mils, um) output is available. Both ISO Standard and ISO\nLow Frequency are DIP switch selectable. RMS or Peak Signal Detection is\n selectable. A Buffered Output signal is available on the screw terminals, or the signals can be connected to a din rail mount BNC Module like the \u003ca href=\"\/products\/cmcp300e-bnc-interface-module\"\u003eCMCP300E\u003c\/a\u003e. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eAccelerometer or Velocity Input\u003c\/li\u003e\n\u003cli\u003eAcceleration, Velocity or Displacement Output\u003c\/li\u003e\n\u003cli\u003eSingle Level of Integration\u003c\/li\u003e\n\u003cli\u003eRMS or Peak Detection\u003c\/li\u003e\n\u003cli\u003eEnglish or Metric Selectable\u003c\/li\u003e\n\u003cli\u003eISO Standard 10 Hz - 1 kHz or\u003c\/li\u003e\n\u003cli\u003eISO Low Frequency 2 Hz - 2 kHz\u003c\/li\u003e\n\u003cli\u003eSelectable Filters\u003c\/li\u003e\n\u003cli\u003eBuffered Output Terminal\u003c\/li\u003e\n\u003cli\u003e4 mA Sensor Power\u003c\/li\u003e\n\u003cli\u003eSlimline DIN Rail Mount\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":48343510909140,"sku":"STI-CMCP700S-CV","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/STI-CMCP700S-CV-2.jpg?v=1785184320"},{"product_id":"cmcp700s-dc-transmitter-forthrust-position-temperature-dc","title":"CMCP700S-DC Transmitter forThrust Position, Temperature, DC","description":"The \u003cb\u003eCMCP700S-DC Transmitter\u003c\/b\u003e can be used with any standard or long range\nProximity Probe System to monitor Thrust Position, or Turbine\nDifferential Expansion. The CMCP700S-DC creates -24VDC onboard for\nproximity sensor system power. \u003cbr\u003e\u003cbr\u003eOther parameters such as Case Expansion\nusing a DC LVDT, or Temperature from a Solid State Temperature Sensor\ncan also be monitored and easily DIP switch selectable. \u003cbr\u003e\u003cbr\u003eA Buffered Output signal is available on the screw terminals, or the signals can be connected to a din rail mount BNC Module like the \u003ca href=\"\/products\/cmcp300e-bnc-interface-module\"\u003eCMCP300E\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eProximity System Input\u003c\/li\u003e\n\u003cli\u003eDisplacement (mils\/mm) Output\u003c\/li\u003e\n\u003cli\u003eSolid State Temperature Input\u003c\/li\u003e\n\u003cli\u003eTemperature Output\u003c\/li\u003e\n\u003cli\u003e-24VDC Created Onboard\u003c\/li\u003e\n\u003cli\u003eEnglish or Metric Selectable\u003c\/li\u003e\n\u003cli\u003eDC Detection\u003c\/li\u003e\n\u003cli\u003eSlimline Din Rail Mounted\u003c\/li\u003e\n\u003cli\u003ePower On with Red LED Indication\u003c\/li\u003e\n\u003cli\u003eBuffered Output on Terminal \u003c\/li\u003e\n\u003cli\u003e5 Selectable Ranges\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":48343511236820,"sku":"STI-CMCP700S-DC","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/STI-CMCP700S-DC-2.jpg?v=1785184321"},{"product_id":"cmcp700s-rv-relative-vibration-transmitter","title":"CMCP700S-RV Relative Vibration Transmitter","description":"The \u003cb\u003eCMCP700S-RV (Relative Vibration)\u003c\/b\u003e accepts a Proximity Probe Sensor\nInput and creates -24 VDC onboard for sensor power. Standard input is\n200 mv\/mil (7.87 mv\/um) and the CMCP700S-RV provides an output in\nDisplacement (mils, um). Signal Detection is “Peak to Peak”.\n\u003cbr\u003e\u003cbr\u003eA Buffered Output signal is available on the screw terminals, or the signals can be connected to a din rail mount BNC Module like the \u003ca href=\"\/products\/cmcp300e-bnc-interface-module\"\u003eCMCP300E\u003c\/a\u003e. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eProximity System Input\u003c\/li\u003e\n\u003cli\u003eDisplacement (mils\/um) Output\u003c\/li\u003e\n\u003cli\u003e-24VDC Created Onboard\u003c\/li\u003e\n\u003cli\u003eEnglish or Metric Selectable\u003c\/li\u003e\n\u003cli\u003ePeak to Peak Detection\u003c\/li\u003e\n\u003cli\u003eSlimline Din Rail Mounted\u003c\/li\u003e\n\u003cli\u003ePower On with Red LED Indication\u003c\/li\u003e\n\u003cli\u003eBuffered Output on Terminal\u003c\/li\u003e\n\u003cli\u003e5 Selectable Ranges\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":48343511466196,"sku":"STI-CMCP700S-RV","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/STI-CMCP700S-RV-2.jpg?v=1785184322"},{"product_id":"cmcp730d-display-relay-module","title":"CMCP730D Display\/Relay Module for Current, Voltage or Temperature Sensors","description":"\u003cp\u003eThe \u003cb\u003eSTI CMCP730D\u003c\/b\u003e is a DIN rail mounted display\/relay module for current, voltage or temperature sensors. It is STI's replacement for the discontinued CMCP560 RTD, CMCP565 thermocouple and CMCP580 temperature transmitters.\u003c\/p\u003e\u003cp\u003eContact us for configuration details or a quote.\u003c\/p\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":67888227877076,"sku":"CMCP730D","price":495.0,"currency_code":"USD","in_stock":true}]},{"product_id":"cmcp700s-cvt-vibration-temperature-transmitter","title":"CMCP700S-CVT Dual Parameter Vibration and Temperature Transmitter","description":"\u003cp\u003eThe \u003cb\u003eSTI CMCP700S-CVT\u003c\/b\u003e is a slimline DIN rail mounted dual parameter transmitter providing both vibration and temperature outputs. It is STI's replacement for the discontinued CMCP700S-CV case vibration transmitter.\u003c\/p\u003e\u003cp\u003eContact us for configuration details or a quote.\u003c\/p\u003e","brand":"STI Vibration Monitoring, Inc.","offers":[{"title":"Default Title","offer_id":67888227942612,"sku":"CMCP700S-CVT","price":495.0,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/sejqw6-v1.myshopify.com\/collections\/transmitters-din-rail.oembed","provider":"Reliability Direct Store, LLC","version":"1.0","type":"link"}