CMCP530 Velocity Transmitter
The CMCP530 Accelerometer based
Velocity Transmitter is available in either "Peak" or "True RMS" signal
detection versions and English or Metric scaling. The CMCP530 is
compatible with all 100mV/g output accelerometers, and provides a 4-20
mA output proportional to the overall measurement. Each unit provides
constant current power for the accelerometer, checks for faults,
processes the vibration signal to determine overall amplitude, and
outputs a 4-20 mA dc current that is proportional to a user selectable
range of 0.5, 1.0, 1.5, 2.0 and 2.5 in/sec (metric equivalent of 12.7,
25.4, 38.1, 50.8 and 63.5 mm/sec) with a 100 mv/g Input. Combining
transmitters with an existing PLC or DCS system results in a high
density, low cost vibration monitoring system.
Buffered Output:
A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs.
Fault Detection:
On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to <2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.
Filters:
For applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.
Alarms relays and trip multiply are available with the Monitor version
Alarms - The CMCP500A Series Monitors have
two independent set points, with LED alarm indicators and output relay contacts
(Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110%
of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay
contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.
Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.
Specifications
| Input | Accelerometer (100 mv/g) |
|---|---|
| Power | +24 Vdc @ 45 mA max. (30 mA typical). |
| Protection | Reverse polarity and transient protection. |
| Frequency Response (wo/filters) | (-3 dB) 10 Hz to 1 kHz. |
| Buffered Output | BNC Connector 0-20 kHz. |
| Accuracy | 0.5 % of Full Scale Range. |
| Output | 4-20 mA proportional to the full scale range. |
| Maximum Load | 600 Ohms Resistive. |
| Case | Isolated. |
| Range | 5, 10, 15, 20, or 25 g's (100 mv/g Input) |
| Constant Current Diode | 4.0 mA |
| Fault Indication | Green LED and 4-20 mA < 2mA |
| Alarms | OK, Alert and Danger |
|---|---|
| Alarm Setpoints | Alert and Danger Adjustable 0 to 110% FS. |
| Trip Multiply | 2X or 3X on Contact Closure. |
| Alarm Relays | OK, Alert and Danger.
Form C, SPDT, 5A @ 30 VDC or 250 VAC. |
| Time Delay | 0.1, 1, 3, 6 or 10 Seconds, Selectable. |
| Alarm LED's | Alert = Yellow, Danger = Red. |
| Display Outputs | 0-5 VDC for Current Value, Alert Setpoint and Danger Setpoint. |
| Operating Temp. | -20°C to +80°C (-4°F to +176°F). |
|---|---|
| Storage Temp. | -55°C to +125°C (-67° F to +257°F). |
| Relative Humidity | 0 - 95% Non-Condensing. |
| Mounting | 32 mm (G style) or 35 mm (T style) DIN Rail. |
|---|---|
| Size | Transmitter 1.0" Wide x 3.11" High x 3.95" Deep |
Shipping
| Carriers | UPS or FedEx for domestic orders; FedEx for international orders |
|---|---|
| Shipping cost | Calculated automatically at checkout for US orders. International orders require a complete ship-to address with postal code. |
| Freight terms | FOB shipping point, freight prepaid. Title passes to the buyer at the vendor's dock. |
| Hazardous items | Epoxy adhesives, batteries and paint markers cannot ship by air freight |
| International | Shipping fees do not include taxes, tariffs or duties |
Returns
| Return window | 7 calendar days from delivery. Contact us before returning any item. |
|---|---|
| Condition | New, unaltered and unused. Special and custom orders are not returnable. |
| Restocking fee | 15% on non-defective items that are not being exchanged |
| Full policy | Refund / Return Policy |
See our Shipping & Billing Terms for how estimated shipping is charged, and our Refund / Return Policy.
Questions about shipping on this item? Call (214) 238-0493 or contact us.