CMCP570 Solid State Temperature Transmitter
The CMCP570 Solid State Temperature Transmitter is compatible with Accelerometers with internal solid state temperature sensing elements such as the 793T and 797T. It is available in English or Metric scaling. The CMCP565 provides constant current power, checks for faults, processes the temperature signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a range of 0 to 250° F (-17.8 to 121°C). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
The Optional Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
Alarms relays and trip multiply are available with the Monitor version.
Alarms - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.
Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.
Trip Multiply - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up.
Fault Detection:
Specifications
| Input | Accelerometers with Solid State Temperature. (793T and 797T) |
|---|---|
| Power | +24 Vdc @ 45 mA max. (30 mA typical). |
| Protection | Reverse polarity and transient protection included. |
| Accuracy | 0.5 % of Full Scale Range. |
| Output | 4-20 mA proportional to the full scale range. |
| Maximum Load | 600 Ohms Resistive. |
| Constant Current Source | 4 mA CCD |
| Case | Isolated. |
| Range | English, 0 to 250° F. |
| Fault Indication | Green LED and 4-20 mA < 2mA |
| Alarms | OK, Alert and Danger |
|---|---|
| Alarm Setpoints | Alert and Danger Adjustable 0 to 110% FS. |
| Trip Multiply | 2X or 3X on Contact Closure. |
| Alarm Relays | OK, Alert and Danger.
Form C, SPDT, 5A @ 30 VDC or 250 VAC. |
| Time Delay | 0.1, 1, 3, 6 or 10 Seconds, Selectable. |
| Alarm LED's | Alert = Yellow, Danger = Red. |
| Display Outputs | 0-5 VDC for Current Value, Alert Setpoint and Danger Setpoint. |
| Operating Temp. | -20°C to +80° C (-4° F to +176° F). |
|---|---|
| Storage Temp. | -55°C to +125° C (-67° F to +257° F). |
| Relative Humidity | 0 - 95% Non-Condensing. |
| Mounting | 32 mm (G style) or 35 mm (T style) DIN Rail. |
|---|---|
| Size | Transmitter 1.0" Wide x 3.11" High x 3.95" Deep |
Shipping
| Carriers | UPS or FedEx for domestic orders; FedEx for international orders |
|---|---|
| Shipping cost | Calculated automatically at checkout for US orders. International orders require a complete ship-to address with postal code. |
| Freight terms | FOB shipping point, freight prepaid. Title passes to the buyer at the vendor's dock. |
| Hazardous items | Epoxy adhesives, batteries and paint markers cannot ship by air freight |
| International | Shipping fees do not include taxes, tariffs or duties |
Returns
| Return window | 7 calendar days from delivery. Contact us before returning any item. |
|---|---|
| Condition | New, unaltered and unused. Special and custom orders are not returnable. |
| Restocking fee | 15% on non-defective items that are not being exchanged |
| Full policy | Refund / Return Policy |
See our Shipping & Billing Terms for how estimated shipping is charged, and our Refund / Return Policy.
Questions about shipping on this item? Call (214) 238-0493 or contact us.