{"product_id":"extech-an100-cfm-cmm-thermo-anemometer","title":"Extech AN100 CFM\/CMM Thermo-Anemometer","description":"\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eCFM\/CMM Thermo-Anemometer + IR Thermometer\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-STYLE: italic\"\u003eLarge display of Airflow or Air Velocity\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"FONT-STYLE: italic\"\u003e\u003c\/span\u003e\u003cspan style=\"FONT-STYLE: italic\"\u003ePlus model with built-in InfraRed Thermometer\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eFeatures:\u003c\/span\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"FONT-WEIGHT: bold\"\u003e\u003c\/span\u003eModel AN100 ? CFM\/CMM Thermo-Anemometer \n\u003c\/li\u003e\n\u003cli\u003eSimultaneous display of Ambient Temperature and Air Flow or Air Velocity \n\u003c\/li\u003e\n\u003cli\u003eUp to 8 easy to set Area dimensions (ft 2 or cm2) are stored in the meter?s internal memory \n\u003c\/li\u003e\n\u003cli\u003e20 point average function for Air Flow \n\u003c\/li\u003e\n\u003cli\u003eSuper large LCD Backlit Display \n\u003c\/li\u003e\n\u003cli\u003e3% velocity accuracy via low friction 2.83\"D (72mm) ball bearing vane wheel on 3.9ft (120cm) cable \n\u003c\/li\u003e\n\u003cli\u003eData Hold and MIN\/MAX \n\u003c\/li\u003e\n\u003cli\u003eAuto Power off \n\u003c\/li\u003e\n\u003cli\u003eComplete with vane sensor with 3.9ft (120cm) cable, 9V battery, protective rubber holster, and carrying case \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eApplications:\u003c\/span\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"FONT-WEIGHT: bold\"\u003e\u003c\/span\u003eHVAC installation, repair, diagnostics, and optimization. \n\u003c\/li\u003e\n\u003cli\u003eFume hood testing, installation, and verification \n\u003c\/li\u003e\n\u003cli\u003eVentilation system installation, servicing, and analysis \n\u003c\/li\u003e\n\u003cli\u003eEnvironmental wind and temperature testing\/analysis \n\u003c\/li\u003e\n\u003cli\u003eBoiler rooms \n\u003c\/li\u003e\n\u003cli\u003eIonizer flow output monitoring \n\u003c\/li\u003e\n\u003cli\u003eAutomobile aerodynamic testing \n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003ePlant\/Facilities Maintenance\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cp\u003e\n\u003c\/p\u003e\u003ctable style=\"WIDTH: 100%; BORDER-COLLAPSE: collapse\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eSpecifications\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eRange\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eResolution\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eBasic Accuracy\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eAir Velocity\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0.40 to 30.00 m\/s\u003c\/div\u003e\n\u003cdiv\u003e1.4 to 108.0 km\/h\u003c\/div\u003e\n\u003cdiv\u003e80 to 5906 ft\/min\u003c\/div\u003e\n\u003cdiv\u003e0.9 to 67.2 mph\u003c\/div\u003e\n\u003cdiv\u003e0.8 to 58.3 knots\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0.01 m\/s\u003c\/div\u003e\n\u003cdiv\u003e0.1 km\/h\u003c\/div\u003e\n\u003cdiv\u003e1 ft\/min\u003c\/div\u003e\n\u003cdiv\u003e0.1 mph\u003c\/div\u003e\n\u003cdiv\u003e0.1 knots\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e±3% m\/s\u003c\/div\u003e\n\u003cdiv\u003e±3% km\/h\u003c\/div\u003e\n\u003cdiv\u003e±3% ft\/min\u003c\/div\u003e\n\u003cdiv\u003e±3% mph\u003c\/div\u003e\n\u003cdiv\u003e±3% knots\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eAir Temperature\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e14 to 140°F (-10 to 60°C)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0.1°F\/°C\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e±6.0°F (3°C)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eInfraRed Temperature\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003e(AN200 Only)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-58 to -4°F (-50 to -20°C)\u003c\/div\u003e\n\u003cdiv\u003e-4 to 500°F (-20 to 260°C)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0.1°F\/°C\u003c\/div\u003e\n\u003cdiv\u003e1°F\/°C\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e±9.0°F (5.0°C)\u003c\/div\u003e\n\u003cdiv\u003e±2% reading or ±2°F (°C) whichever is greater\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eAirflow\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0 to 9999 CMM (m3\/min)\u003c\/div\u003e\n\u003cdiv\u003e0 to 9999 CFM (ft3\/min)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0.1\u003c\/div\u003e\n\u003cdiv\u003e0.1\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"FONT-WEIGHT: bold\"\u003eDimensions\/Weight\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e 7 x 2.9 x 1.3\" (178 x 74 x 33mm)\/1.6lbs (700g)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003c\/p\u003e\n\n\u003cdiv\u003e\n\u003cspan style=\"FONT-WEIGHT: bold; TEXT-DECORATION: underline\"\u003e\u003c\/span\u003e \u003c\/div\u003e\n","brand":"Extech Instruments Corp.","offers":[{"title":"Do Not Include NIST","offer_id":48343335239892,"sku":"EXT-AN100","price":224.0,"currency_code":"USD","in_stock":true},{"title":"Include NIST Calibration Certificate","offer_id":48343335272660,"sku":"EXT-AN100-NIST","price":321.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/EXT-AN100-2.jpg?v=1785144387","url":"https:\/\/sejqw6-v1.myshopify.com\/products\/extech-an100-cfm-cmm-thermo-anemometer","provider":"Reliability Direct Store, LLC","version":"1.0","type":"link"}