{"product_id":"tpi-183a-true-rms-digital-multimeter-with-temperature-capacitance-duty-cycle-low-pass-filter","title":"TPI-183A True RMS Digital Multimeter with temperature, capacitance, duty cycle, \u0026 low-pass filter","description":"\u003cspan style=\"font-weight: bold;\"\u003e\u003c\/span\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eTrue RMS DMM with temperature, capacitance, duty cycle, \u0026amp; low-pass filter \u003c\/span\u003e\u003cbr\u003e\n\u003c\/p\u003e\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd class=\"style4\"\u003e\n\u003cli\u003e4,000 count \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrue RMS for more accurate  measurements \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuto\/manual ranging \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature measurement \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDuty cycle to measure the amount of time the \n            motor is on \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow pass filter for noisy environments \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeparate fuse (2) and \t\tbattery compartment \t\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuto power off \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIR serial interface\u003c\/li\u003e\n\u003cli\u003ecULus 61010-1\u003c\/li\u003e\n\u003cli\u003eCAT II - 1000V, CAT III - 600V\n                \u003c\/li\u003e\n\u003cli\u003e3 Year Limited Warranty\u003c\/li\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e\n\u003c\/p\u003e\u003cbr\u003e\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd class=\"style4\"\u003e\n\u003cli\u003eTest run and start capacitors \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasure ambient and duct temp. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest control (thermostat, thermocouple, flame \n                safety) and line voltages \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasure resistance and test for continuity \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLine current up to 10 amps (in series) \u003c\/li\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" width=\"340\"\u003e\u003ctbody\u003e\n\u003ctr align=\"left\" bgcolor=\"#DCE14E\" style=\"color: rgb(255, 255, 255);\"\u003e\n\u003cth bgcolor=\"#000000\" colspan=\"2\" height=\"30\" scope=\"col\" valign=\"middle\"\u003e\u003cspan class=\"style2\"\u003e\u003cimg height=\"28\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/tpiLogoSmall.gif?v=1784674765\" width=\"35\"\u003e \u003cspan class=\"style3\"\u003e183A Specifications \u003c\/span\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd width=\"126\"\u003eDC Volts \u003c\/td\u003e\n\u003ctd width=\"188\"\u003e\n\u003cp\u003eMaximum  Input: 1000V \u003cbr\u003e\n      Maximum Resolution: 0.01mV \u003cbr\u003e\n      Accuracy: +\/-0.5% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eAC Volts \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 750V \u003cbr\u003e\n      Maximum Resolution: 0.01mV Accuracy: +\/-0.75% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eDC Amps \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 10A \u003cbr\u003e\n      Maximum Resolution: 0.01µA Accuracy: +\/-0.8% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eAC Amps \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 10A \u003cbr\u003e\n      Maximum Resolution: 0.1µA Accuracy: +\/-1.2% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eResistance (Ohms) \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 40MΩ \u003cbr\u003e\n      Maximum Resolution: 0.1Ω Accuracy: +\/-0.5% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eFrequency \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 10MHz Maximum Resolution: 0.01Hz Accuracy: +\/-0.05% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eCapacitance \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum  Input: 4000µF Maximum Resolution: 0.01nF Accuracy: +\/-3% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eInductance \u003c\/td\u003e\n\u003ctd\u003eN\/A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eTemperature (K-Type  Thermocouple) \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Input: 2372°F  (1300°C) Maximum Resolution: 0.1°F \/ °C Accuracy: +\/-2% \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eContinuity \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAudible at less than 30Ω \u003c\/p\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eDiode \u003c\/td\u003e\n\u003ctd\u003e2.7V at 1mA maximum output \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eDuty Cycle \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange:  0.1 to 99.9%\u003cbr\u003e\n      Accuracy: 0.1% + 1 count\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eTrue RMS Responding \u003c\/td\u003e\n\u003ctd\u003eYes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eConductance \u003c\/td\u003e\n\u003ctd\u003eNo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003ePulse Width \u003c\/td\u003e\n\u003ctd\u003eNo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eData Hold \u003c\/td\u003e\n\u003ctd\u003eYes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eMin\/Max Record \u003c\/td\u003e\n\u003ctd\u003eYes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eTime Stamp Logging \u003c\/td\u003e\n\u003ctd\u003eNo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eRelative Mode \u003c\/td\u003e\n\u003ctd\u003eYes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" width=\"340\"\u003e\u003ctbody\u003e\n\u003ctr align=\"left\" bgcolor=\"#DCE14E\" style=\"color: rgb(255, 255, 255);\"\u003e\n\u003cth bgcolor=\"#000000\" height=\"30\" scope=\"col\" valign=\"middle\"\u003e\u003cspan class=\"style2\"\u003e\u003cimg height=\"28\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/tpiLogoSmall.gif?v=1784674765\" width=\"35\"\u003e \u003cspan class=\"style3\"\u003e163 Applications \u003c\/span\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eThermocouples in furnaces or gas applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eHeat anticipator current in thermostats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eVoltage of direct drive DC motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eControl circuit voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eMotor run and start capacitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eFlame safeguard control current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eHeating element resistance (continuity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eCompressor winding resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eContactor and relay coil resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eContinuity of wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eContinuity of circuit breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eTemperature w\/ optional temperature adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#FFFFFF\"\u003e\n\u003ctd\u003eBar graph to indicate rapid fluctuations in measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Test Products International, Inc.","offers":[{"title":"Default Title","offer_id":48343544725716,"sku":"TPI-183A","price":175.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/0451\/2724\/files\/TPI-183A-1.gif?v=1785148011","url":"https:\/\/sejqw6-v1.myshopify.com\/products\/tpi-183a-true-rms-digital-multimeter-with-temperature-capacitance-duty-cycle-low-pass-filter","provider":"Reliability Direct Store, LLC","version":"1.0","type":"link"}