Test Products International, Inc.

TPI-196 Process Meter with 0-24 mA output for process loop calibration

$263.95
SKU: TPI-196
Qty
Request a Quote
✓ Authorized Dealer ✓ 7-Day Returns ✓ Expert Support
Description
Specifications
Shipping & Returns
0-24 mA output built in for process loop calibration, 0.05% accuracy, 50,000 counts, DMM with separate fuse and battery compartment
  • Process DMM with 0 to 24mA output
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV; max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; max resolution 0.01uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CAT II-1000VDC, 750VAC, CATIII-600V
  • Limited Life time Warranty
196 Specifications
DC Volts Maximum Input: 1000V

Maximum Resolution: 0.0001mV

Accuracy: +/-0.05%

AC Volts Maximum Input: 1000V

Maximum Resolution: .001mV

Accuracy: +/-0.4%

DC Amps Maximum Input: 1A

Maximum Resolution: 0.0001mA

Accuracy: +/-0.5%

AC Amps Maximum Input: 1A

Maximum Resolution: 0.0001mA

Accuracy: +/-0.75%

Resistance (Ohms) Maximum Input: 50MΩ

Maximum Resolution: 0.01Ω

Accuracy: +/-0.05%

Frequency Maximum Input: 500KHz

Maximum Resolution: 0.01Hz

Accuracy: +/-0.05%

Capacitance N/A
Inductance N/A
Temperature

(K-Type Thermocouple)

N/A
Continuity Audible at less than 30Ω
Diode 3V at 1mA maximum output
Duty Cycle N/A
True RMS Responding No
Conductance No
Pulse Width No
Data Hold Yes
Min/Max Record Yes
Time Stamp Logging No
Relative Mode Yes
Compare Mode Yes
RS-232 Output Yes, Optically Isolated
Process Loop Output Yes (0 to 24mA)
Sleep Mode / Auto Off Yes
Protective Boot Yes (standard)
Display Type 50,000 count backlit LCD with dual sub displays and analog bargraph
Range Selection Auto / Manual
Operating Temperature 32°F to 113°F (0°C to 40°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Humidity 80% non-condensing
Size 8.3? x 3.7? x 1.9? (210mm x 95mm x 47mm) without boot

8.7? x 4.3? x 2.6 (220mm x 110mm x 65mm) with boot

Weight 1.3lbs (570g) without boot

1.9lbs (850g) with boot

Battery Type 9V Alkaline (NEDA 1604)
Battery Life 50hrs Typical
OverInput Category CAT III 600V
Agency Approval cULus 61010-1, IEC 61010-1
Warranty Limited Lifetime


196 Applications
Thermocouples in furnaces or gas applications
Heat anticipator current in thermostats
Line voltage
Control circuit voltage
Flame safeguard control current
Heating element resistance (continuity)
Compressor winding resistance
Contactor and relay coil resistance
Continuity of wiring
Motor start and run capacitance
Frequency on controls and line voltages
Record min/max voltage of controls and line voltages
Temperature with optional temperature adapter (A310)
Bar graph to indicate rapid fluctuations in measurements
Voltage of direct drive DC motors
Measure power supply voltage
Match components
Compare readings in circuits and components
Frequency of line and control voltage


Contact us at (214) 238-0493 for full specifications.

Shipping

CarriersUPS or FedEx for domestic orders; FedEx for international orders
Shipping costCalculated automatically at checkout for US orders. International orders require a complete ship-to address with postal code.
Freight termsFOB shipping point, freight prepaid. Title passes to the buyer at the vendor's dock.
Hazardous itemsEpoxy adhesives, batteries and paint markers cannot ship by air freight
InternationalShipping fees do not include taxes, tariffs or duties

Returns

Return window7 calendar days from delivery. Contact us before returning any item.
ConditionNew, unaltered and unused. Special and custom orders are not returnable.
Restocking fee15% on non-defective items that are not being exchanged
Full policyRefund / Return Policy

See our Shipping & Billing Terms for how estimated shipping is charged, and our Refund / Return Policy.

Questions about shipping on this item? Call (214) 238-0493 or contact us.